Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 43
Filter
1.
Dent Traumatol ; 2024 Mar 08.
Article in English | MEDLINE | ID: mdl-38459667

ABSTRACT

BACKGROUND/AIMS: The study aimed to assess the surface characteristics of sports mouthguards under mechanical stresses during cleaning, either by brushing or immersion in disinfectant solutions. MATERIAL AND METHODS: Ethylene-vinyl acetate samples, 4 mm thick, were randomly assigned to cleaning methods: control (C-no cleaning), brushing with water (B.W), brushing with neutral liquid soap (B.S), brushing with toothpaste (B.T), immersion in distilled water for 10 min (I.W), immersion in 2.25% sodium hypochlorite solution for 10 min (I.SH), and immersion in sodium bicarbonate solution for 5 min (I.SB). All cleaning methods were applied for 28 days. Surface roughness average (Ra) and wettability were measured at baseline for the control group (n = 9), and after cleaning for all the other groups. RESULTS: One-way ANOVA with Tukey tests (5% significance) indicated significant differences among groups (p < .05). The I.SB group had higher surface roughness than B.S and B.T (p < .05). B.W showed the lowest wettability, significantly lower than B.T, I.W, and I.SB (p < .05). I.SB exhibited the highest wettability, significantly different from sodium hypochlorite, neutral liquid soap, brushing with water, and control groups (p < .05). The sodium bicarbonate immersion group (I.SB) demonstrated greater statistical variation, displaying higher susceptibility to aging compared to brushing with neutral liquid soap. CONCLUSION: Cleaning mouthguards with a toothbrush, water, and neutral liquid soap emerged as the most promising method, causing minimal surface changes in the material.

2.
Braz. dent. sci ; 26(4): 1-7, 2023. ilus
Article in English | LILACS, BBO - Dentistry | ID: biblio-1523154

ABSTRACT

Objective: The study aimed to develop a cell phone application entitled: "Total Prosthesis Manual ­ Rehabilitating smiles", as an auxiliary teaching tool for teachers and students through digital technology, with a smartphone. Material and Methods: The tool was structured on the "Application Factory website", which allows the creation of mobile applications in different formats, with broad and interactive features on IOS and Android platforms. The expository format of the content is in slide format, containing descriptive theory and images about the stages of making a complete prosthesis; from necessary materials, photos and descriptive guidance of the steps. Results: The application is a complementary teaching resource to assist undergraduate and postgraduate students and professionals working in the area of complete prosthetics. The theoretical and practical content selected for the application covered all stages of understanding, development and possible complications associated with the manufacture of a complete bimaxillary prosthesis, from planning, impressions, models, orientation plans, tooth assembly, adaptations and delivery. Conclusion: The application provided a low-cost, expandable and easy-to-use teaching resource for teaching complete dentures. It is essential to develop various analyzes such as user experience tests, application effectiveness, development of new technologies and improvement of techniques, so that their potential for enriching learning in complete dentures and dentistry in general can be verified.(AU)


Objetivo: O estudo teve como objetivo desenvolver um aplicativo de celular intitulado: "Manual de Prótese Total ­ Reabilitando sorrisos", como uma ferramenta didática auxiliar para professores e alunos por meio da tecnologia digital, com smartphone. Material e Métodos: A ferramenta foi estruturada no "site da Fábrica de Aplicativos", que permite a criação de aplicativos móveis em diversos formatos, com recursos amplos e interativos nas plataformas IOS e Android. A modalidade expositiva do conteúdo é em formato de slides, contendo teoria descritiva e imagens sobre as etapas de confecção de uma prótese total; a partir de materiais necessários, fotos e orientação descritiva das etapas. Resultados: O aplicativo é um recurso didático complementar para auxiliar estudantes de graduação, pós-graduação e profissionais que atuam na área de prótese total. O conteúdo teórico e prático selecionado para a aplicação visou todas as etapas de compreensão, desenvolvimento e possíveis complicações associadas à confecção de uma prótese total bimaxilar, desde o planejamento, moldagens, maquetes, planos de orientação, montagem dos dentes, adaptações e entrega. Conclusão: O aplicativo trouxe um recurso didático de baixo custo, expansível e fácil de usar para o ensino de próteses totais. É fundamental desenvolver diversas análises como testes de experiência do usuário, eficácia de aplicação, desenvolvimento de novas tecnologias e aprimoramento de técnicas, de forma que possa ser verificado seu potencial de enriquecimento do aprendizado em prótese total e odontologia em geral(AU)


Subject(s)
Humans , Educational Technology , Denture, Complete , Education, Dental , Mobile Applications , Education, Distance , Dentists/education
3.
Polymers (Basel) ; 14(20)2022 Oct 13.
Article in English | MEDLINE | ID: mdl-36297884

ABSTRACT

Soft reliner and glaze are materials used over full or partial dental prosthesis to prevent excessive pressure on the supporting tissues. They are also indicated as supportive treatment for dental stomatitis, especially when modified by the addition of medications. The objective of the work was to evaluate the antimicrobial effect of silver-coated silica nanoparticles in a glaze and a soft reliner. The nanoparticles were synthesized, characterized, and tested by minimum inhibitory concentration (MIC) for C. albicans SC5314. Then, the nanoparticles were incorporated to a glaze and a soft reliner, which were called nanocomposites. Then, the nanocomposites were divided into six groups (n = 12): CG: glaze/reliner; CR: reliner; G1: glaze + 1% nanoparticles/reliner; G2: glaze + 2.5% nanoparticles/reliner; R1: reliner + 1%; R2: reliner + 2.5%. The nanocomposites were characterized by a goniometer and by a scanning electron microscope. The antibiofilm test was performed against C. albicans SC5314. According to the MIC results, the non-functionalized nanoparticles reduced fungal growth at 1000 µg/mL and the functionalized nanoparticles at 2000 µg/mL. The functionalized nanoparticle had a superior dispersion being selected for the antibiofilm test. There was a reduction of 64% in CFU/specimen count for the glaze, not statistically significant (p = 0.244). For the soft reliner, there was an increase in CFU/specimen with the presence of nanoparticles, still not statistically significant (p = 0.264). In conclusion, it is necessary to conduct new studies to increase the release of silver, thus improving nanoparticles' antifungal potential.

4.
J Adhes Dent ; 24(1): 325-333, 2022 Aug 18.
Article in English | MEDLINE | ID: mdl-35980241

ABSTRACT

PURPOSE: To evaluate the effect of irradiation with an optical-fiber device on the bond strength of hollow and partially opaque intraradicular posts. MATERIALS AND METHODS: An optical-fiber accessory tip was attached to a light-curing unit to emit light through the central hollow of an experimental fiberglass post. The samples were divided into 4 groups (n = 80) according to the protocol (Variolink N [light cured] or Multilink N [dual-curing luting material]) and the light-curing mode (performed conventionally or with the optical fiber): GF: light-curing luting material; GFF: light-curing luting material and optical fiber; GD: dual-curing luting material; GDF: dual-curing luting material and optical fiber. The samples were tested immediately or after aging. Push-out bond strength, failure mode, degree of conversion (DC, assessed at the peak of 1750 cm-1), and stress distribution by finite element analysis were performed. Quantitative data were analyzed using 3-way ANOVA (luting material x light curing x depth) and 2-way ANOVA (aging x luting material), followed by Tukey's test. RESULTS: Bond strength was significantly affected by the luting material protocol (p < 0.001), depth (p = 0.010), and light curing mode (p = 0.031). The GFF group revealed higher bond strength in the middle and apical portions. The most frequent failure modes were adhesive in the apical portion for the GFF and GDF groups. The DC was higher for GF and GFF groups. CONCLUSION: Using the optical-fiber device led to superior bond strength results when a dual-curing luting material was used.


Subject(s)
Dental Bonding , Post and Core Technique , Dental Bonding/methods , Dentin , Materials Testing , Optical Fibers , Resin Cements/chemistry , Surface Properties
5.
Braz. dent. sci ; 25(3): 1-9, 2022. tab, ilus
Article in English | LILACS, BBO - Dentistry | ID: biblio-1373077

ABSTRACT

Objective: Thermally activated acrylic resins (RAATs) are widely used in dentures as a base material due to their good dimensional stability and biocompatibility. However, their low thermal conductivity is a disadvantage, as it affects acceptance when using dental prostheses. Thus, the objective of this work was to measure the conduction heat in RAATs with and without incorporation of silica and silver nanoparticles (NP) and rigid reline (RR). Material and Methods: For this, samples were made and divided into 10 groups (n = 6). The first five groups were 2-mm-thick samples: G1 (RAAT control), G2 (RAAT + RR control), G3 (RAAT and NP + RR), G4 (RAAT + RR and NP), and G5 (RAAT and RR modified by NP). In the other five groups, 8-mm-thick samples were made: G6 (RAAT control), G7 (RAAT + RR control), G8 (RAAT and NP + RR), G9 (RAAT + RR and NP), and G10 (RAAT and RR modified by NP). The heat that cross the surface of the specimens was quantified using a wireless device. The data were submitted to two-factor ANOVA statistical analysis and Tukey ́s test with a 5% significance level. Results: After measuring the temperature variation as a function of time, it can be observed that there was a statistically significant difference for thermal conduction between the control groups and those modified with NP. Conclusion: Thus, it was possible to conclude that the NP improved the heat conduction in RAAT and in the RR because the nanoparticles have a higher thermal conductivity. (AU)


Objetivo: As resinas acrílicas termicamente ativadas (RAATs) são amplamente utilizada em próteses dentárias como material de base, pois possuem uma boa estabilidade dimensional e biocompatibilidade. Porém, como desvantagem, possuem baixa condutividade térmica, o que prejudica a aceitação do uso de próteses dentárias. Assim, o objetivo deste trabalho foi medir a condução de calor em RAAT com e sem incorporação de nanopartículas de sílica e prata (NP) e reembasador rígido (RR). Material e Métodos: Para isso, foram confeccionadas amostras que foram divididas em 10 grupos (n=6). Os primeiros cinco grupos eram amostras de 2 mm de espessura: G1 (RAAT controle), G2 (RAAT + RR controle), G3 (RAAT e NP + RR), G4 (RAAT + RR e NP) e G5 (RAAT e RR modificados por NP). E nos outros cinco grupos foram feitas amostras com espessura de 8 mm: G6 (RAAT controle), G7 (RAAT + RR controle), G8 (RAAT e NP + RR), G9 (RAAT + RR e NP) e G10 (RAAT e RR modificados por NP). O calor percorrido pela superfície dos corpos ­ de prova foi quantificado por meio de um dispositivo sem fio. Os dados foram submetidos à análise estatística ANOVA dois fatores e teste de Tukey com 5% de significância. Resultados: Após medir a variação da temperatura em função do tempo, pode-se observar que houve diferença estatisticamente significante para a condução térmica entre os grupos controle e os modificados com NP. Conclusão: Assim, foi possível concluir que a NP melhorou a condução de calor na RAAT e no RR, pois as nanopartículas apresentam maior condutividade térmica. (AU)


Subject(s)
Thermal Conductivity , Acrylic Resins , Nanoparticles , Metal Nanoparticles
6.
Arch. health invest ; 10(7): 1141-1146, July 2021. ilus, tab
Article in English | BBO - Dentistry | ID: biblio-1344583

ABSTRACT

This article describes an alternative open tray technique for implant impressions using a novel reinforced silica-nylon mesh covered with acrylic resin as a splitting system in assembling the abutment complex. The purpose of the procedure is to simplify the technique and improve the resin contraction during clinical procedure, and also optimizes and reduces the chairside time for the patient. The clinical report was supported by an in vitrostudy where an analysis tool, Strain Gauge Analysis, was used to prove the clinical effectiveness of the technique. The peri-implant strain was determined on polyurethane casts with the torqued prosthesis, and statistically there was no difference in strain under torque of transfers or in the final prosthesis. The nylon mesh attached to acrylic resin represents a promising option for open tray impression technique, creating a resistant union to transfer in an excellent procedure time(AU)


Este artigo descreve uma alternativa para a técnica de moldeira aberta para moldagem de implantes utilizando uma nova malha de reforço de sílica-nylon coberta por resina acrílica para ferulização dos componentes protéticos. O propósito deste procedimento é simplificar a técnica e compensar a contração da resina durante os procedimentos clínicos, e também otimizar e reduzir o tempo de atendimento do paciente. O relato de caso foi amparado com um estudo in vitroonde uma ferramenta de análise de extensometria, Análise de Strain Gauge, foi utilizada para avaliar a efetividade clínica da técnica. A deformação peri-implantar foi determinada nas bases de poliuretano com a prótese instalada, e estatisticamente não houve diferença estatística na deformação nos torques dos transferentes ou na prótese final. A malha de nylon unida à resina acrílica representa uma opção promissora para a técnica de moldagem com moldeira aberta, criando uma união resistente aos transferentes em um excelente tempo clínico(AU)


Este estudio describe una técnica alternativa de cubeta abierta para impresiones de implantes utilizando una nueva malla de sílice-nylon cubierta con resina acrílica como un sistema de ferulización en montaje del complejo de pilares. El objetivo del procedimiento es simplificar la técnica y mejorar la contracción de la resina durante el procedimiento clínico y también optimiza y reduce el tiempo de atención al paciente. El relato clínico fue respaldado por un estudio in vitro en el que se utilizó unaherramienta de análisis, Análisis de Galgas Extensométricas, para probar la efectividad clínica de la técnica. La deformación periimplantaria se determinó en moldes de poliuretano con la prótesis apretada, y estadísticamente no hubo diferencia en la deformación del torque de los postes o en la prótesis final. La malla de nylon unida a la resina acrílica representa una opción prometedora para la técnica de impresión en cubeta abierta, creando una unión resistente para transferir en un excelente tiempo de procedimiento(AU)


Subject(s)
Humans , Female , Middle Aged , Acrylic Resins , Dental Impression Technique , Dental Prosthesis, Implant-Supported , Nylons , Computer Simulation , Dental Implants , Dental Prosthesis Design , Dental Prosthesis , Silicon Dioxide
7.
J Clin Exp Dent ; 13(5): e505-e510, 2021 May.
Article in English | MEDLINE | ID: mdl-33981399

ABSTRACT

BACKGROUND: Nylon is a polymer that its use to reinforce dental resins has shown positive results such as increased flexural strength. The aim of this study was to evaluate the bond strength between dental resins and a nylon reinforcement. MATERIAL AND METHODS: Forty cylindrical nylon blocks with 13 x 23 mm with 0.5% by volume of silica and 40 without were made. Half of the samples of each nylon composition were sandblasted with aluminum oxide (50µm) for 3 s (2.8 bar pressure, distance: 20 mm, incidence angle: 90o). On the nylon blocks, cylinders of chemically activated acrylic resin and indirect composite resin were made, with a bonding area of 6,28 mm2. Eight different groups were obtained according to the material used and the surface treatment (n = 10): Acrylic Resin + Nylon; GAS: Acrylic Resin + Nylon with Silica; GAT: Acrylic Resin + Nylon (Al2O3); GAST: Acrylic Resin + Nylon with Silica (Al2O3); GC: Composite Resin + Nylon; GCS: Composite Resin + Nylon with Silica; GCT: Composite Resin + Nylon (Al2O3); GCST: Composite Resin + Nylon with Silica (Al2O3). The shear test was carried out. The Student's and the Kruskal-Wallis test was adopted. RESULTS: There was no statistically difference in the bond strength for nylon with silica for the acrylic resin group. For the composite groups, nylon with silica did not present a statistically difference without surface treatment (p = 0.10) and with surface treatment the bond strength decreased (p = 0.000). The GCT showed a higher bond strength (0.89 MPa). The surface treatment improved the bond strength for the both groups. CONCLUSIONS: The presence of silica in the nylon composition did not influence the bond strength between materials evaluated. However, the surface treatment with aluminum oxide proved to be favorable for this adhesion. Key words:Nylons - Resins, Synthetic - Structures Strengthening - Dental Research.

8.
Quintessence Int ; 52(7): 646-651, 2021 Jun 09.
Article in English | MEDLINE | ID: mdl-33880910

ABSTRACT

Systemic scleroderma is a relatively rare, autoimmune, chronic, and debilitating disease, and its etiology is unknown. The disease is characterized by vasomotor disturbances causing skin and mucosa hardening, hand stiffness, excess production of collagen fibers, and impairment of the internal organs associated with the immune system. Extreme mouth-opening limitation is one of the symptoms in the oral cavity, and compromises dental intervention. One of the fundamental steps when performing a dental procedure is dental arch impression. In the presented clinical case, limited mouth opening hindered the impression accuracy. The objective was to present an alternative impression technique for a patient affected by scleroderma, with limited mouth opening and the need for oral rehabilitation with a removable partial prosthesis in the maxillary arch. An individualized tray was developed with design characteristics that allowed access to the oral cavity and removal, after which it was possible to perform the oral impression, reproducing the areas of interest without causing injury to the oral tissues. The orientation plan was elaborated after obtaining the cast. The teeth were assembled, tested in the mouth, and sent to the laboratory for acrylization. The prosthesis was placed once ready. The alternative impression technique enabled oral rehabilitation of the patient despite the mouth-opening limitation, and provided an accurate impression and a good prosthetic result.


Subject(s)
Dental Implants , Microstomia , Scleroderma, Systemic , Dental Impression Technique , Denture Design , Humans
9.
Braz. dent. sci ; 24(2): 1-7, 2021. tab, ilus
Article in English | LILACS, BBO - Dentistry | ID: biblio-1177576

ABSTRACT

Purpose: To evaluate the effect of fibromucosa height on the stress distribution and displacement of mandibular total prostheses during posterior unilateral load, posterior bilateral load and anterior guidance using the finite element analysis (FEA). Material and methods: 3D virtual models were made to simulate the stress generated during different mandibular movements in a total prosthesis. The contacts were simulated according to the physiology, being considered perfectly bonded between cortical and medullar bones; and between cortical bone and mucosa. Non-linear frictional contact was used for the total prosthesis base and fibromucosa, allowing the prosthesis to slide over the tissue. The cortical bone base was fixed and the 100 N load was applied as unilateral load, posterior bilateral load and anterior guidance simulation. The required results were for maximum principal stress (MPa), microstrain (mm/mm) and total displacement (mm). The numerical results were converted into colorimetric maps and arranged according to corresponding scales. Results: The stress generated in all situations was directly proportional to the fibromucosa height. The maximum principal stress results demonstrated greater magnitude for anterior guidance, posterior unilateral and posterior bilateral, respectively. Only posterior unilateral load demonstrated an increase in bone microstrain, regardless of the fibromucosa height. Prosthesis displacement was lower under posterior bilateral loading. Conclusion: Posterior bilateral loading is indicated for total prosthesis because it allows lower prosthesis displacement, lower stress concentration at the base of the prosthesis and less bone microstrain. (AU)


Objetivo: Avaliar o efeito da altura da fibromucosa na distribuição de tensões e deslocamento das próteses totais mandibulares durante a carga unilateral posterior, carga bilateral posterior e orientação anterior usando a análise por elementos finitos (FEA). Material e métodos: Modelos virtuais 3D foram confeccionados para simular a tensão gerada durante diferentes movimentos mandibulares em uma prótese total. Os contatos foram simulados de acordo com a fisiologia, sendo considerados perfeitamente unidos entre os ossos corticais e medulares; e entre o osso cortical e a mucosa. O contato friccional não linear foi utilizado entre a base total da prótese e a fibromucosa, permitindo que a prótese deslizasse sobre o tecido. A base do osso cortical foi fixada e a carga de 100 N aplicada como carga unilateral, carga bilateral posterior e simulação de guia incisiva anterior. Os resultados foram calculados em tensão máxima principal (MPa), microdeformação (mm/mm) e deslocamento total (mm). Os resultados numéricos foram convertidos em mapas colorimétricos e organizados de acordo com as escalas correspondentes. Resultados: A tensão gerada em todas as situações foi diretamente proporcional à altura da fibromucosa. Os resultados de tensão máxima principal demonstraram maior magnitude durante a carga anterior, posterior unilateral e posterior bilateral, respectivamente. Apenas a carga unilateral posterior demonstrou aumento da microdeformação óssea, independente da altura da fibromucosa. O deslocamento da prótese foi menor sob carga bilateral posterior. Conclusão: A carga bilateral posterior é indicada para prótese total, pois permite menor deslocamento da prótese, menor concentração de tensões na base da prótese e menor microdeformação óssea (AU)


Subject(s)
Finite Element Analysis , Dental Occlusion , Denture, Complete
10.
Braz. dent. sci ; 24(4): 1-7, 2021. ilus
Article in English | LILACS, BBO - Dentistry | ID: biblio-1337660

ABSTRACT

Digital dentistry has gained space in several dental specialties. It is possible to achieve excellent results with the digital workflow, which combines the efficiency of the restorative material with a greater marginal adaptation. This study aimed to report a clinical case through the digital workflow, with a faster and clinically acceptable prosthetic resolution. In this clinical case report, digital workflow allowed a faster and clinically acceptable prosthetic resolution. A 45-year-old female patient reported cementation failure of the prosthetic crown on tooth 14. As it was a vital tooth, the tooth received a total crown preparation. In the same clinical session, the patient's mouth was scanned then a capture software obtained a virtual model. After, the design software planned a digital "diagnostic wax-up", so a leucitic ceramic was chosen for the rehabilitation. The ceramic block was milled and receive stain and glaze, dispensing the prosthesis laboratory. Then, the adhesive cementation was performed with a dual-polymerized resin cement. The final crown had ideal adaptation, with no need for interproximal and occlusal adjustments, with an excellent marginal fit. Within the limitations of this study, this case report showed that the digital workflow allowed a favorable result in a shorter working time, which brought back function and aesthetics, without the need for interproximal and occlusal adjustments. (AU)


A odontologia digital vem ganhando espaço em diversas especialidades odontológicas. Com o fluxo de trabalho digital, é possível alcançar excelentes resultados na reabilitação protética, combinando a eficiência do material restaurador com a adaptação marginal proporcionada pela odontologia digital. O objetivo desse estudo foi relatar um caso clínico através do fluxo de trabalho digital, com uma resolução protética mais rápida e clinicamente aceitável. Paciente do sexo feminino, 45 anos, relatou falha de cimentação da coroa protética do dente 26. Por ser um dente vital, o dente recebeu um preparo de coroa total e os dentes foram escaneados e um software de captura obteve um modelo virtual. Posteriormente, o software de projeto planejou um "enceramento diagnóstico" digital, sendo escolhida uma cerâmica leucítica para a reabilitação. O bloco cerâmico foi fresado e recebeu acabamento, maquiagem e glaze pelo próprio dentista, dispensando um técnico laboratorial de prótese dentária. Em seguida, foi realizada cimentação adesiva definitiva. Este relato de caso mostra que, dentro das limitações desse estudo, o fluxo digital permite um resultado favorável em um menor tempo de trabalho, devolvendo a função e estética, sem necessidade de ajustes interproximais e oclusais (AU)


Subject(s)
Humans , Female , Adult , Dental Prosthesis , Computer-Aided Design , Esthetics, Dental
11.
Life (Basel) ; 10(11)2020 Nov 20.
Article in English | MEDLINE | ID: mdl-33233499

ABSTRACT

(1) Background: Trauma is a very common experience in contact sports; however, there is an absence of data regarding the effect of athletes wearing mouthguards (MG) associated with ankylosed maxillary central incisor during a traumatic impact. (2) Methods: To evaluate the stress distribution in the bone and teeth in this situation, models of maxillary central incisor were created containing cortical bone, trabecular bone, soft tissue, root dentin, enamel, periodontal ligament, and antagonist teeth were modeled. One model received a MG with 4-mm thickness. Both models were subdivided into finite elements. The frictionless contacts were used and a nonlinear dynamic impact analysis was performed in which a rigid object hit the model at 1 m·s-1. For each model, an ankylosed periodontal ligament was simulated totaling 4 different situations. The results were presented in von-Mises stress maps. (3) Results: A higher stress concentration in teeth and bone was observed for the model without a MG and with ankylosed tooth (19.5 and 37.3 MPa, respectively); the most promising mechanical response was calculated for patients with healthy periodontal ligament and MG in position (1.8 and 7.8 MPa, respectively). (4) Conclusions: The MG's use is beneficial for healthy and ankylosed teeth, since it acts by dampening the generated stresses in bone, dentin, enamel and periodontal ligament. However, patients with ankylosed tooth are more prone to root fracture even when the MG is in position compared to a healthy tooth.

12.
Braz. dent. sci ; 23(4): 1-7, 2020. ilus
Article in English | BBO - Dentistry , LILACS | ID: biblio-1122343

ABSTRACT

Head and neck cancer occupy the seventh place among the most common neoplasms in the world, with an annual incidence of approximately 640,000 new cases. Radiotherapy treatment has been highlighted, because there is greater tissue preservation, possibility of regression of the disease, decreased tumor volume, prevention of possible tumor recurrences and metastases, and even total cancer cure, but patients undergoing radiotherapy are at high risk of osteoradionecrosis if they perform surgical interventions in the region, such as dental implants and dental extraction, making prosthetic rehabilitation of partially edentulous patients after treating oral cancer something complex and often omitted; although it is a crucial factor in restoring oral function. Thus, the aim of the present study was to describe the planning, treatment and follow-up of a twelve-month prosthetic approach to rehabilitate the lower arch shape and function of a partially edentulous patient undergoing head and neck radiotherapy with a full denture mucus supported and tooth retained. After twelve months of follow-up, it was possible to evidence the functional and aesthetic clinical success, with preserved occlusal pattern, soft and bone tissue around and dental roots. (AU)


O câncer de cabeça e pescoço ocupa o sétimo lugar entre as neoplasias mais comuns do mundo, com uma incidência anual de aproximadamente 640.000 novos casos. O tratamento com radioterapia tem se destacado, pois há maior preservação tecidual, possibilidade de regressão da doença, diminuição do volume tumoral, prevenção de possíveis recorrências e metástases tumorais e até cura total do câncer, mas os pacientes submetidos à radioterapia apresentam alto risco de osteorradionecrose se realizar intervenções cirúrgicas na região, como implantes dentários e extração dentária, fazendo com que a reabilitação protética, de pacientes parcialmente dentados depois de tratar o câncer bucal, algo complexo e frequentemente omitido; embora seja um fator crucial para o reestabelecimento da função oral. Assim, o objetivo do presente estudo foi descrever o planejamento, tratamento e acompanhamento de doze meses de uma abordagem protética para reabilitar forma e função do arco inferior de um paciente parcialmente desdentado, submetido a radioterapia de cabeça e pescoço, com o uso de uma prótese total mucossuportada e dente retida. Após doze meses de acompanhamento, foi possível evidenciar o sucesso clínico funcional e estético, com padrão oclusal, rebordo alveolar e remanescentes dentários preservados (AU)


Subject(s)
Humans , Radiotherapy , Denture, Overlay , Head and Neck Neoplasms , Mouth Rehabilitation
13.
Braz. dent. sci ; 22(3): 305-312, 2019. tab, ilus
Article in English | LILACS, BBO - Dentistry | ID: biblio-1008364

ABSTRACT

Objective: The aim of the study was to evaluate the influence of different surface post-etching treatments in flexural strength, contact angle and surface roughness of a lithium disilicate ceramic. Material and Methods: 60 bars (16 x 2 x 4 mm) were divided in six groups (n=10): C, no treatment; HF, hydrofluoric acid for 20 s (HF) + washing (60 s), drying (30s); HFL, HF + washing (60 s), drying (30 s) and luting; HFNL, HF + washing (60 s) + neutralization with sodium bicarbonate (SB) for 40 s + washing (5s), drying (30 s) and luting; HFUL, HF + washing (60 s) + ultrasonic bath (UB) for 4 min, drying (30 s) and luting; HFNUL, HF + washing (60 s) + SB (40 s) + UB (4 min) and luting. The bars were submitted to three-points flexural strength test. 25 ceramic blocks (12 x 7 x 7 mm) were divided into five groups (n=5) to evaluate roughness and contact angle C - no treatment; HF - HF ; HFU - HF and UB for 5 min ; HFN - HF and SB; HFNU - HF, UB and SB. A scanning electron microscope (SEM) showed the surface of the samples. ANOVA one-way statistical analysis was done for comparison of results. Results: There was no statistical difference for flexural strength (p-value = 0.15) and for surface roughness (p-valor = 0.15). However, it was obtained statistically significant difference for contact angle (p-valor = 0.00). SEM images showed precipitates after the acid etching, which were removed by post-etching treatments. Conclusion: It can be concluded that the different post-etching surface treatments did not increase the flexural strength, surface roughness, but it influenced the ceramic wetting and SEM images (AU)


Objetivo: O objetivo do estudo foi avaliar a influência de diferentes tratamentos pós-condicionamento na resistência à flexão, ângulo de contato e rugosidade superficial de uma cerâmica de dissilicato de lítio. Material e Métodos: 60 barras (16 x 2 x 4 mm) foram divididas em seis grupos (n = 10): C, sem tratamento; HF, ácido fluorídrico durante 20 s (HF) + lavagem (60 s), secagem (30 s); HFL, lavagem com HF + (60 s), secagem (30 s) e cimentação; HFNL, HF + lavagem (60 s) + neutralização com bicarbonato de sódio (SB) por 40 s + lavagem (5s), secagem (30 s) e cimentação; HFUL, HF + lavagem (60 s) + banho ultrassônico (UB) por 4 min, secagem (30 s) e cimentação; HFNUL, HF + lavagem (60 s) + SB (40 s) + UB (4 min) e cimentação. As barras foram submetidas ao teste de resistência à flexão de três pontos. 25 blocos cerâmicos (12 x 7 x 7 mm) foram divididos em cinco grupos (n = 5) para avaliação da rugosidade superficial e ângulo de contato C - sem tratamento; HF - HF; HFU - HF e UB por 5 min; HFN - HF e SB; HFNU - HF, UB e SB. Um microscópio eletrônico de varredura (MEV) foi utilizado para análise da superfície das amostras. A análise estatística unidirecional ANOVA-um fator foi realizada para comparação dos resultados. Resultados: Não houve diferença estatística para a resistência à flexão (p-valor = 0,15) e para a rugosidade superficial (p-valor = 0,15). No entanto, obteve-se diferença estatisticamente significante para o ângulo de contato (p-valor = 0,00). Imagens de microscopia eletrônica de varredura mostraram a formação de precipitados após o ataque ácido, que foram removidos pelos tratamentos pós-condicionamento. Conclusão: Pode-se concluir que os diferentes tratamentos de superfície pós-condicionamento não aumentaram a resistência à flexão, rugosidade da superfície, mas influenciaram na molhabilidade da cerâmica e nas imagens em MEV.(AU)


Subject(s)
Electron Microscope Tomography , Flexural Strength , Hydrofluoric Acid
14.
J Prosthet Dent ; 119(4): 606-610, 2018 Apr.
Article in English | MEDLINE | ID: mdl-28709676

ABSTRACT

STATEMENT OF PROBLEM: Complete-arch implant-supported prostheses without a framework have a high risk of failure: a straightforward and inexpensive reinforcement material, such as nylon mesh, could improve their longevity. PURPOSE: The purpose of this in vitro study was to evaluate a nylon-silica mesh compound on the fracture strength of acrylic resin and the fracture load of complete-arch implant-supported prostheses. MATERIAL AND METHODS: Twenty-four complete mandibular arch implant-supported prostheses were divided into 2 groups according to cantilever length (molar and premolar) and subdivided into another 2 subgroups according to the presence or absence of reinforcing mesh. The specimens were submitted to a maximum load-to-fracture test in a universal testing machine, with a 100-N load cell, a 2 mm/min crosshead speed, and a spherical metal tip diameter of 4 mm at different points (molar and premolar). These were submitted to 1-way analysis of variance for repeated measurement and the post hoc Tukey multiple comparison test (α=.05). RESULTS: The mean maximum load ±standard deviation for the molar group was 393.4 ±95.0 N with reinforcement and 305.4 ±76.3 N without reinforcement (P=.02); and for the premolar group was 1083.3 ±283.7 N with reinforcement and 605.3 ±90.5 N without reinforcement (P=.001). CONCLUSIONS: Reinforcement with nylon mesh increased the mean maximum load of implant-supported complete-arch prostheses at both cantilever lengths. The cantilever to the premolar (5 mm) presented the highest maximum load values to fracture.


Subject(s)
Dental Prosthesis, Implant-Supported , Dental Stress Analysis , Materials Testing , Nylons , Silicon Dioxide , Humans , In Vitro Techniques , Jaw, Edentulous/rehabilitation , Mastication
15.
Braz. dent. sci ; 21(3): 302-306, 2018. tab
Article in English | LILACS, BBO - Dentistry | ID: biblio-911402

ABSTRACT

Objective: Evaluate the influence of different disinfection methods on the dimensional stability of temporary acrylic resin crowns. Material and Methods: A metallic die with two different marks at the margin was used to prepare the specimens with two different resins (bis-acrylic resin-Structur, acrylic resin-Dencrilay). They were divided into eight groups (n=8), determined according to the disinfection methods (microwave, acetic acid, 1% hypochlorite) and control. The marginal adaptation was recorded using an optical microscope (50X) comparing two different marks on the margin of the crowns with 2 points along the entire circumferential margin before and after disinfection methods. Results: Results were compared statistically by ANOVA and Tukey's test (p≤0.05). The two-way ANOVA showed statistical difference between types of materials. No significant differences were found between disinfection methods and interaction of factors. Conclusion: All procedures affected the marginal adaptation however temporary crowns made by bis-acrylic resin demonstrate higher dimensional stability. (AU)


Objetivo: Avaliar a influência de diferentes métodos de desinfecção na estabilidade dimensional de coroas temporárias de resina acrílica. Material e Métodos: um molde metálico com duas marcas diferentes na margem foi utilizado para preparar os espécimes com duas resinas diferentes (resina bis-acrílica - estrutura, resina acrílica-Dencrilay). Eles foram divididos em oito grupos (n = 8), determinados de acordo com os métodos de desinfecção (microondas, ácido acético, 1% de hipoclorito) e controle. A adaptação marginal foi registrada usando um microscópio óptico (50X) comparando duas marcas diferentes na margem das coroas com 2 pontos ao longo de toda a margem circunferencial antes e após os métodos de desinfecção. Resultados: os resultados foram comparados estatisticamente por ANOVA e teste de Tukey (p≤0,05). A ANOVA de dois fatores mostrou diferença estatística entre os materiais utilizados. Não foram encontradas diferenças significativas entre os métodos de desinfecção e a interação dos fatores. Conclusão: Todos os procedimentos afetaram a adaptação marginal, porém as coroas temporárias feitas em resina bis-acrílica demonstram maior estabilidade dimensional. (AU)


Subject(s)
Acrylic Resins , Biomedical and Dental Materials , Dental Materials , Disinfection , Tooth Crown
16.
Prótesenews ; 4(4): 440-452, out.-nov. 2017. ilus
Article in Portuguese | BBO - Dentistry | ID: biblio-877171

ABSTRACT

O esmalte dentário é o único tecido duro que não apresenta remodelação. Qualquer distúrbio que ocorra durante o processo de desenvolvimento e maturação do esmalte resulta em anomalias neste tecido. A hipoplasia do esmalte pode ser consequência de eventos sistêmicos, traumáticos, ambientais ou genéticos. De acordo com o grau de severidade desta anomalia, vários protocolos de tratamento podem ser realizados em restaurações estéticas diretas e laminados ou coroas unitárias, como clareamento, microabrasão e mega-abrasão. O objetivo deste trabalho foi relatar a condução de avaliação e tratamento de um caso clínico de hipoplasia de esmalte de uma paciente que mostrava insatisfação com tamanho e cor dos dentes anteriores. Foi realizada como resolução clínica a gengivoplastia e laminados cerâmicos nos dentes anteriores superiores.


The dental enamel is the only hard tissue that does not remodel itself. Any disorder that occurs during the enamel development and maturation process results in tissue abnormalities. Enamel hypoplasia may be a consequence of systemic, traumatic, environmental or genetic events. According to the degree of severity of this anomaly, several treatment protocols can be perfomed, from bleaching, microabrasion, megaabrasion, direct aesthetic restorations and laminates or single crows. The aim of this work is to present a clinical case of enamel hypoplasia of a patient who reported dissatisfaction with the size and color of the teeth. For this, gingivoplasty and ceramic laminates were performed on the upper anterior teeth.


Subject(s)
Humans , Female , Adult , Composite Resins , Dental Enamel Hypoplasia/therapy , Dental Veneers , Esthetics, Dental , Tooth Abnormalities/therapy
17.
Braz. dent. sci ; 19(2): 139-144, 2016. ilus
Article in English | LILACS | ID: lil-788620

ABSTRACT

Clinicians can find patients with one mandibular remaining tooth, and it is difficult to decide if the tooth has to be removed. When a clinician decides to maintain the tooth, it is common to question the masticatory load distribution divided between the tooth and implant. This paper reports a clinical case of patient with an implant/tooth-supported overdenture and elucidates the masticatory efficiency by electromyography activity analysis. The objective of this case report was to describe a clinical case of a patient with an implant/tooth-supported overdenture and to discuss the muscle response to this treatment. Electrical activities of the masseter and anterior temporal surfaces at maximum voluntary contraction were evaluated by electromyography during pre-treatment, immediately post-treatment,15 and 60 days after installation. When patienthas one remaining tooth in good condition, theimplant/tooth-supported overdenture can be recommended, to preserve the periodontal ligament and proprioception, and to minimize bone loss. Electromyography analysis showed that implant/tooth-supported overdenture is a viable treatment alternative, in muscular stand point, when the patient has a remaining tooth with good osseous support...


Os dentistas podem encontrar casos em que o paciente possui apenas um dente mandibular remanescente,sendo difícil decidir se o dente deverá ser extraído. Quando o clínico decide manter este dente, é comum surgirem dúvidas sobre como ocorre a distribuição da carga mastigatória em próteses suportadas por dente e implante. Este artigo relata a resposta muscular por meio de atividade eletromiográfica de um paciente reabilitado com uma prótese inferior implantodentossuportada. O objetivo deste artigo foi descrever este caso clínico e discutir a resposta musculatória neste tipo de tratamento. As atividades eletromiográficas dos músculos massetere temporal anterior superficial foram avaliadas durante o pré-tratamento, imediatamente após a instalação da prótese, 15 e 60 dias pós-tratamento.Foi verificado que quando o paciente tem um dente remanescente em condição de ser mantido, a prótese implantodentossuportada pode ser recomendada como tratamento, para preservação do ligamento periodontal e da propriocepção, e para minimizar a perda óssea. A análise eletromiográfica demonstrou que a prótese implantodentossuportada é uma alternativa viável de tratamento, do ponto de vista muscular, quando o paciente possui um dente remanescente com suporte ósseo adequado...


Subject(s)
Humans , Dental Implantation , Prostheses and Implants
18.
Braz. j. oral sci ; 12(2): 84-89, Apr.-June 2013. ilus
Article in English | LILACS, BBO - Dentistry | ID: lil-694423

ABSTRACT

Aim: To evaluate the influence of plaster condition, dry or not, on the amount of residual monomerin heat-cured acrylic resin. Methods: Thirty acrylic resin specimens (65x10x3 mm) were fabricatedand randomly assigned to 5 groups (n=6). The evaluated resins were heat-cured acrylic resinsby conventional or microwave polymerization techniques and the plaster was previously dried inmicrowave oven in two groups. Each specimen was individually immersed in a test tube containingmethanol (7 days) for surface analysis. In the groups for which internal monomer was evaluated,the specimens were fragmented and the small fragments were weighed prior to immersion inmethanol. The analysis was made by high performance liquid chromatography (HPLC). Datawere analyzed by ANOVA and Tukey test (p<5%) Results: showed statistical differences amongthe groups. Conclusions: The previous plaster drying influenced the residual monomer amountshowing a decrease of these levels.


Subject(s)
Acrylic Resins , Chromatography , Research , Polymers
19.
RPG rev. pos-grad ; 19(2): 50-56, abr.-jun. 012. tab
Article in Portuguese | LILACS, BBO - Dentistry | ID: lil-688226

ABSTRACT

Este estudo teve o propósito de investigar as propriedades flexurais de seis marcas comerciais de resinas compostas indiretas e duas resinas compostas para uso direto. Dez espécimes (2 x 2 x 12 mm) de cada material foram confeccionados de acordo com as recomendações dos fabricantes: Grupo I - Signum (Heraeus Kulzer), Grupo 2 - Solidex (Shofu Inc.), Grupo 3 - Resilab (Wilcos), Grupo 4 - Adoro (Ivoclair Vivadent), Grupo 5 - Admira (Voco), Grupo 6 - Sinfony (3M/Espe), Grupo 7 - Filtek Supreme (3M/ESPE) e Grupo 8 - Venus (Heraeus Kulzer). Os espécimes foram armazenados a 37 graus por 24 horas. Em seguida, foram submetidos ao ensaio de miniflexão na máquina de Ensaio Universal EMIC a uma velocidade de 0,75 mm/min, para determinar o módulo de elasticidade e resistência à flexão três pontos para cada compósito estudado.


Subject(s)
Composite Resins , Elastic Modulus , Fatigue
20.
Braz. dent. sci ; 15(4): 10-13, 2012. ilus, tab
Article in English | LILACS, BBO - Dentistry | ID: lil-694453

ABSTRACT

Objectives: To investigate the effect of the thermal treatment on the bending strength of ceramic bars (VM7) treated by the cementation protocol. Material and Methods: Forty ceramic bars (20 x 4 x 1.2 mm) were constructed and randomly distributed into 2 groups (n=20): NT - without treatment/control and T – with treatment (50°C above the glass transition temperature, for 15 min). All specimens underwent the cementation process in which one surface of the ceramic bar was etched (20 s) with 10% hydrofluoridric acid, followed by air-water jet washing (60 s), drying (30 s), silane agent application and resin cementation. After storage (distilled water/seven days at 37 ºC), the specimens were submitted to 3-point flexure test at 100% humidity/37 ºC (v=1 mm/min, load cell of 10 kgf). Results: The bending strength values and standard deviations (MPa) were: NT: 19.98 (3.17)a; T: 20.45 (4.67)a (one-way ANOVA and Tukey test, σ=0.05). Conclusions: The thermal treatment did not influence on the bending strength mean values of the ceramics studied.


Objetivos: Investigar o efeito do tratamento térmico, na resistência à flexão, de barras cerâmicas (VM7) tratadas pelo protocolo de cimentação. Material e Métodos: Foram confeccionadas 40 barras cerâmicas (20 x 4 x 1.2 mm) e distribuídas randomicamente em 2 grupos (n=20): NT - sem tratamento/controle e T - com tratamento (50°C acima da temperatura de transição de fases, durante 15 min). Todos os espécimes receberam o processo de cimentação onde uma face da barra cerâmica foi condicionada (20 s) com ácido fluorídrico 10%, seguida pela lavagem jato ar-água (60 s), secagem (30 s), aplicação do silano e cimentação resinosa. Após armazenagem (água destilada/sete dias à 37 ºC), as amostras foram submetidas ao ensaio de flexão 3 pontos em 100% umidade à 37 ºC (v=1 mm/min, célula de carga de 10 kgf). Resultados: Os valores de resistência à flexão e os desvios-padrão (MPa) para os grupos foram: NT: 19.98 (3.17)a; T: 20.45 (4.67)a (ANOVA one-way e Teste de Tukey, σ=0.05). Conclusões: Verificou-se que o fator tratamento térmico não influenciou nos valores médios de resistência à flexão da cerâmica estudada.


Subject(s)
Resin Cements , Thermic Treatment
SELECTION OF CITATIONS
SEARCH DETAIL
...